Daikin Air Conditioner error codes
Select a Daikin air conditioner error code to see what it means, common causes, and how to fix it.
Error Codes
H7
The outdoor unit fan motor signal is abnormal
H8
The compressor input current transformer (CT) system has a fault
H9
The outdoor air thermistor has a fault
HC
The hot water temperature thermistor has a fault
J1
The outdoor unit pressure sensor has a fault
J2
The compressor current sensor has a fault
J3
The discharge pipe thermistor has a fault
J4
The low pressure equivalent saturated temperature sensor has a fault
J5
The outdoor unit suction pipe thermistor has a fault
J6
The outdoor unit heat exchanger thermistor has a fault
J7
A refrigerant circuit thermistor (liquid pipe) has a fault
J8
A refrigerant circuit thermistor (liquid pipe, second) has a fault
J9
A refrigerant circuit gas pipe thermistor has a fault
JA
The high pressure sensor has a fault
JC
The low pressure sensor has a fault
L0
The inverter system has a fault — possible power supply capacity shortage
L1
The inverter PCB has a fault
L3
The electrical component box temperature rose abnormally
L4
The inverter radiation fin temperature rose abnormally
L5
The inverter detected an instantaneous overcurrent from the DC output