Daikin · Air Conditioner
Daikin Air Conditioner AJ error code
Difficulty: Hard
·
Cost: $80–$250
·
Duration: Requires professional service
The AJ error means your Daikin air conditioner detected a capacity setting fault. This typically occurs after an indoor unit PCB has been replaced without installing the capacity setting adaptor, or the PCB itself is defective. Contact a qualified technician to install the correct capacity setting adaptor.
Common causes
- Capacity setting adaptor was not installed after replacing the PCB
- Defective indoor unit PCB
How to fix it
-
1
Contact a qualified technician to install the correct capacity setting adaptor or inspect the PCB
Related Daikin Air Conditioner error codes
1
A0
An external protection device connected to the indoor unit has been activated
hard
2
A1
A fault was detected in the indoor unit PCB (control board)
hard
3
A3
The drain level control system has detected an abnormality — drain may be clogged
medium
4
A5
Freeze-up protection (cooling) or high pressure control (heating) has activated — check the air filter
easy