Daikin · Air Conditioner
Daikin Air Conditioner E3 error code
Difficulty: Medium
·
Cost: $0–$250
·
Duration: 20–30m
The E3 error means your Daikin air conditioner's high pressure switch (HPS) was activated — the refrigerant pressure in the system exceeded safe limits and the unit shut down to protect the compressor. The most common cause is a dirty outdoor unit heat exchanger restricting heat dissipation. Clean the outdoor unit coil fins. If the error persists contact a qualified technician.
Common causes
- Outdoor unit heat exchanger coil fins are dirty or blocked with debris reducing heat dissipation
- Refrigerant piping is clogged
- High pressure switch is defective
- Thermistor connector contact is poor
How to fix it
-
1
Turn off the air conditioner
-
2
Clean the outdoor unit heat exchanger coil fins — use a soft brush or gently rinse with water to remove dust, leaves, and debris
-
3
Make sure there is sufficient clearance around the outdoor unit for airflow
-
4
Restart the air conditioner and check if E3 returns
-
5
If E3 persists after cleaning the outdoor unit contact a qualified technician