Daikin · Air Conditioner
Daikin Air Conditioner L9 error code
Difficulty: Medium
·
Cost: $0–$500
·
Duration: 5m
The L9 error means your Daikin air conditioner's inverter compressor failed to start. A common installation-related cause is a closed stop valve on the refrigerant piping. Check that all refrigerant stop valves on the outdoor unit are fully open. If they are open contact a qualified technician.
Common causes
- Stop valve on the refrigerant piping is not open
- Compressor is defective
- Wiring connections to the compressor are incorrect
- High differential pressure prevented compressor startup
- Inverter PCB has a fault
How to fix it
-
1
Check that all refrigerant stop valves on the outdoor unit are fully open — this is especially relevant for newly installed systems
-
2
If stop valves are fully open and the error persists contact a qualified technician to inspect the compressor and inverter PCB